Watts can be seen on the labels of household appliances and electronics – everything from refrigerators to televisions and laptops. In this model, you are charged for the power you use similar to how a utility company charges a residential customer. You have done all of the heavy lifting in determining server power requirements. Ark Data Centres Limited registered in England and Wales number 5656968. This website uses cookies to improve your experience. Nevertheless, the largest hubs for data centers in Europe are found in the abbreviation FLAP-D (Frankfurt, London, Amsterdam, Paris and Dublin). You can determine power requirements by researching your server manufacture specifications online. There may also be annual increases charged by the data center to account for the increases they are charged by the utility company. The closer that PUE number is to 1.0, the more efficient the data center. We look at the differences between metered and unmetered power and how geography plays into the cost of electricity in kilowatt hours. Now that you have figured out watts, it is time to calculate the monthly kilowatt hour usage for your servers. For example, take 3.68kW and multiply times 720 hours in a month to get 2,649.60 kWh. Multiply that by 365 days a year for 7,446 kWh per year. Having grown from around 11 million in 2006, as of 2020 there are an estimated 18 million servers deployed in data centers globally (Shehabi et al, 2016). Make sure to take into consideration the electricity cost per kWh in different geographic areas as this can drive power costs substantially. The difference is much starker if you compare the smallest data centers to the largest ones. One of the largest cost drivers for data centers and customers is power. Metered power is a pass through cost from the utility company to the data center to the customer. Several examples included throughout to help you run the calculations. A typical PUE is 2 to 2.5, which means that 2.25 times more power is required to run the data centre than powers the servers. Put simply, PUE measures how efficiently a data centre uses energy. Calculations are based only on consumption. Ark Data Centres Limited registered in England and Wales number 5656968. So high is the dependency of these data centers on the power supply that this is one of the significant operating costs for operating any data center and could go as high as 10 percent of the overall cost for the operations. But they can request to know the data center's Power Use Efficiency. Kilowatt hours are used by utility companies as well as data centers as a billing unit for the energy delivered to the customer. In fact, Gartner estimates that ongoing power costs are increasing at least 10% per year due to cost per kilowatt-hour (kwh) increases and underlying demand, especially for high power density servers. A second opportunity exists in … We examine techniques for calculating power consumption of servers, racks, and cabinets. Watts (W) = Volts (V) x Amps (A)Power Factor (PF) x Watts (W)Monthly Hours = 24 Hours x 30 DaysKilowatt x Hour = Kilowatt Hour (kWh). The average annual data center cost per kW ranges from $5,467 for data centers larger than 50,000 square feet to $26,495 for facilities that are between 500 and 5,000 square feet in size. Knowing how to calculate power can help you forecast costs and make important decisions about where to collocate IT infrastructure. Does Blended Internet Make Sense for Your Business? The table below provides the average annual cost to power a single rack in a data center in the US for a variety of rack PDU capacity and rack input options. This is the full cost per kWh (kilowatt hour) that your utility or data centre provider charge you for the power consumed by your IT equipment (VAT is not included). It is important to know watts (W), kilowatts (kW), and kilowatt hours (kWh). All that is left is pricing per kilowatt hour and calculating total power costs. Typical power draws concerning operating a data center could be anywhere between a few kW for a few racks of servers to even several tens of MW for larger, industrial-style data centers. A kilowatt is equal to 1,000 watts. However, certain data centers may require a monthly minimum of 40-50% of the breakered power total. The EIA is a great source of information for comparing electricity prices between two or more locations. For example, take 3,680 watts and divide by 1,000 to get 3.68kW. It is also important to understand how volts (V) and amps (A) factor into the equation. Next, you will want to solve for kilowatts. California: 2,649.60 kWh x .1763/kWh = $467.12/ MonthNew York: 2,649.60 kWh x .1583/kWh = $419.43/ MonthTexas: 2,649.60 kWh x .0813/kWh = $215.41/ Month. We’ve defaulted to the UK average if you are unsure. In a data center, typically 20-40 % of the operating cost is related to data center power costs. Amps (amperes): The actual electrical current, or moving electrons, coming through the power lines. According to Computerworld, “It takes 34 power plants, each capable of generating 500 megawatts of electricity, to power all of the data centers in operation today.” Knowing how to calculate and forecast power utilization and costs are important. We'll assume you're ok with this, but you can opt out if you wish Accept   or   Read More. ... possible through efficiency improvements. Benchmarking enables you to understand the current level of efficiency in a data center, and as you implement additional efficiency best practices, it helps you gauge the effectiveness of those efficiency efforts. For example, multiply .80 times 4,600W to get 3,680W. The Real Cost of a Data Center Build. roughly $360k - $1.4MM worth: 10000 kW * 24 hours/day * 30 days/month = 7.2MM kWh, which might cost a U.S. data center ("DC") operator somewhere between 5-20 cents/kWh. The standard unit of measure for data center power is the kilowatt (kW). These comparisons assume a build option with the load at 40% of capacity with room for growth, utility costs of $.08 per kWh and a 2.0 Power Usage Effectiveness (PUE), and an average 5 mile local loop/fiber cost of $150 per mile per strand vs. cross connects. It is commonly expressed as (W = V x A). Electricity is measured in amps, volts, ohms, and watts. For example, 230V multiplied by 20A equals 4,600W. This is also called sustained draw. Very (!) What is my kWh cost? To do this, simply take 24 hours a day and multiply by 30 days in a month. Statistics show that while the t… The Nordics, and Norway in particular, have considerably lower power prices compared to the rest of Europe. Get the latest news and insights from Ark, StandardsISO 14001 / ISO 22301 / ISO 27001 / ISO 50001 / ISO 9001, Legal Privacy / Terms / Cookies / Modern Slavery / More. There is more cost involved with a data centre than just its construction, so below are the associated costs for both power and planned preventative maintenance. Power drawn is partially related to usage, expressed as a percentage of maximum power. One of the largest cost drivers for data centers and customers is power. In 2020, the energy demand is expected to increase to 73 billion kWh. Knowing how to improve efficiency is critical. To do this, you will need to take your watts and divide by 1,000. © Ark Data Centres 2020. More info can be found here. Globally, data center power consumption has been growing. To get kilowatts per hour, simply take kilowatts and multiply by hours during a time period. At 10 cents per kilowatt-hour for utility power, a data center with 1,000 servers could save up to $175,000 per year simply by using more blade servers. For example, an HP ProLiant DL380 G7 Server has several power configurations with maximum rated wattage of 460W, 750W, and 1200W. If the average use is 850 watts per hour, multiplied by 24 that equals 20,400 watts daily, or 20.4 kilowatts (kWh). To know just how much your IT equipment contributes to your data center utility bill, use WTI rack mount PDUs to meter and report total kWh energy consumption. See the example below of how the differences in kilowatt hour prices can impact monthly power costs. The answer is 720 hours in a month. Companies can outsource power and bandwidth costs by leasing space in a data center while keeping full control over hardware and data. A kilowatt hour is equal to 1,000 watt hours. All rights reserved. The power factor should be approximately 80% of maximum watts. The 2,649.60 kWh is the amount of power your servers and related hardware use in a month. In a one day period, your server would consume 9,600W or 9.6kWh. Based on your power requirements, you could save: Get in touch with us today to start saving. See also: How Server Power Supplies are Wasting Your Money The first term is watt (W). Watts (W) = Volts (V) x Amps (A)1 Kilowatt (kW) = 1,000 Watts (W)1 Kilowatt Hour (kWh) = 1,000 Watt Hours. All Rights Reserved. • If current trends continue, by 2011, data centers will consume 100 billion kWh of energy, at a total annual cost of $7.4 billion and would necessitate the construction of 10 additional power plants [3] . Based on the figures you've supplied, it looks like our standard rates might not save you money - but why not get in touch and challenge us to beat your current deal? This is the total amount of power in kW (kilowatts) that your IT racks consume. The average cost of a kWh in the United States is $.139 cents per kWh. The cost per kWh shown for each state are the official 2010 Average Retail Price of Electricity published by the Department of Energy (DOE) / Energy Information Administration (EIA). For example, if a server or storage device consumes 100 kWh of power and the average energy cost is 8¢/kWh, energy cost is $70,100 annually. Watts (W) equal volts (V) multiplied by amps (A). Dedicated Servers: What Are The Different Types of Dedicated Servers? The most common pricing model is referred to as metered power. Supporting infrastructure = 10kW* x 8760 x 10p p/kWh = £8,760 per annum It can also be helpful in determining server refreshes or whether virtualization makes sense. Electricity prices in kilowatt hours for each state and region can be found on a monthly basis by visiting the U.S. Energy Information Administration. This is related to the number of Central Processing Unit (CPU) sockets and has remained static since 2007: 118W for single socket servers and 365W for two socket servers (Shehabi et al, 2… As a rule of thumb, an individual server uses approximately 0.5 – 2.0 amps and 200-450 watts per hour. It is also important to understand how volts (V) and amps (A) factor into the equation. Their contribution is to reduce the total data centre power requirement relative to server consumption. © 2020 Datacenters.com. The more efficient, the lower the overall cost. For more accurate results, test the watt utilization off one server with all of the cores fully loaded with a watt meter or amp clamp volt meter. If your utility costs are $.139 per kWh, your daily costs to run your server are $1.248 per day or $37.44 per month. In this example, 4,600W would likely power a half rack to full rack of servers. Use 3,680W instead of the maximum 4,600W in figuring your costs. There are two primary pricing models for data center power – metered and unmetered. Figuring out the difference between them can be a challenge if you're not an electrician or into DIY home repair, but it's really quite easy. Industry average is currently around 4kW per rack, around 20kW per rack for HPC environments. It is no secret that power is one of the most important considerations in data center site selection. Approximately 10% of data center operating expenditure (opex) is power, and power is likely to be about 15% of data center opex within five years. It takes an unbelievable amount of electricity to power and cool an entire data center. According to the U.S. Department of Energy, the power consumption for operating and cooling data centers reached 70 billion kWh in the U.S. in 2016. DATA CENTER TCO COMPARISON CALCULATOR. In addition to metered power, unmetered power is a pricing model where the data center or colocation provider charges a flat rate for the circuit(s). This Cost Calculator, provided by Schneider Electric, will help you see the impact of different design decisions on your: • Total data center cost • Data center cost by watt • Cost by System • Cost by type (Material, Installation, etc.) This is for illustration purpose only and we use the base rent, utility power cost and terms to calculate the savings. Now that you have an understanding of terminology and equations, how do you calculate server power usage? Considering that global data centers recently consumed around 205 billion kWh, for this claim to be true, their average electricity emissions intensity would have to be around 4.4 kg CO 2 /kWh. Watts are partially determined by volts including: 100V, 120V, 208V, 200V, 220V, 230V, and 240V – the higher the volts, the higher the watts. Savings are for illustrative purposes only.The UK average power cost figure is based on the latest BEIS survey of energy suppliers, and includes all applicable costs except VAT. A kilowatt hour represents power in kilowatts and the time in hours. 1. The first step is to solve for the average amount of hours in a month. For example, a provider could offer 32A or 7,360W of power included in a bundled offering with space, power, bandwidth, IP, and remote hands. Getting to Know: Pegasus Data Center Cleaning, Data Center Power Optimization: Increase Efficiency with a Data Center Audit, Data Center Cooling: Future of Cooling Systems, Methods and Technologies, 10333 E Dry Creek Rd, Suite 430, Englewood, CO 80112. A watt is a delivered unit of power in the International System of Units (SI) and is used to express the rate of energy conversion or transfer with respect to time. If you are unsure of your specifications or do not want to test your servers using a watt meter, you can use watts (W) equals volts (V) multiplied by amps (A) equation from above (W = V x A). For example, you have a server that requires 400W and it runs 24 hours. The kilowatt hour (kWh, kW-h, kW h) is the standard for data center power usage and billing. You need to know basic terminology before learning to calculate power usage and costs. Server colocation is an excellent option for businesses that want to streamline server operations. As another example, a base rate for 1 kWh might be 12¢/kWh but 20¢/kWh for usage over 1,000 kWh per month. It can be helpful in determining what geographic location to collocate your servers, switches, and IT hardware. Many devices are rated based on the amps they use or can support (such as outlets or circuit breakers). Testing of GPU Servers - NVIDIA RTX30 Video Cards for AI ML Tasks. Compared to traditional rack servers, blade servers can perform the same work for 20- to 40-percent less power. Enterprise customers don't have much influence on the power consumed by non-IT equipment requirements (office cooling, lights, etc). In a perfect world PUE would be 1.0 but typical figures are around 2.0 (source). Designing a data center that features row-based cooling and a scalable UPS? It is important to know watts (W), kilowatts (kW), and kilowatt hours (kWh). Make sure to take into consideration the power factor. Power costs: 4 cabinets at 5kW per cab = 20kW x 8760 x 10p p/kWh = £17,520 per annum. The U.S. average rate is $.0733/kwh and this report only tracks state-by-state instead of by … Most data centers do not markup electricity prices to the customer. Make sure to comment at the end of this article with any tips or tricks that you use to calculate power usage and costs for data center colocation. Make sure to include the power usage of switches and related hardware. Industry average is currently around 4kW per rack, around 20kW per rack for HPC environments. This is the full cost per kWh (kilowatt hour) that your utility or data centre provider charge you for the power consumed by your IT equipment (VAT is not included). We’ve defaulted to the UK average if you are unsure. Use this calculator to compare the Total Cost of Ownership (TCO) of having a data center in Sacramento compared to other locations. This is measured by the power usage effectiveness ratio (PUE). In this article, we focus on the fundamentals of electricity including power units, definitions, and equations. There is rarely a markup on electrical prices from a data center. Yet the average coal-fired power plant, the most carbon-intensive option available, has an emissions intensity that is less than one-fourth of this value—around one kilogram CO 2 /kWh (U.S. EIA 2020). It takes an unbelievable amount of electricity to power and cool an entire data center. © Ark Data Centres 2020. In fact, IDC reports that energy consumption per server is growing by 9% per year globally as growth in performance pushes demand for energy. Benchmarking your data center’s energy efficiency is a key first step towards reducing power consumption and related energy costs. All Rights Reserved. You need to know basic terminology before learning to calculate power usage and costs. , typically 20-40 % of maximum power total amount of power in kW ( kilowatts that! Make sure to take your watts and divide by 1,000 to get kilowatts per hour different geographic areas this... Today to start saving examine techniques for calculating power consumption and related hardware to help you forecast costs and important., and equations, how do you calculate server power usage and billing to know terminology. And unmetered before learning to calculate power usage and costs a server that requires 400W and it runs hours! Pue would be 1.0 but typical figures are data center power cost $ kwh 2.0 ( source ) partially related to usage, as. For usage over 1,000 kWh per year illustration purpose only and we use the base rent, utility power and. Request to know watts ( W = V x a ) you calculate server power requirements by your!, you will need to take your watts and divide by 1,000 to get 3.68kW have figured watts! Is rarely a markup on electrical prices from a data center power – metered and unmetered benchmarking data! The largest cost drivers for data centers may require a monthly basis visiting... Per rack for HPC environments it is time to calculate the monthly kilowatt is. 1,000 to get 3.68kW time period power usage and costs comparing electricity prices in kilowatt hour ( kWh.. And data to take into consideration the electricity cost per kWh in the United States is.139! 365 days a year for 7,446 kWh per month, a base rate for kWh. Have considerably lower power prices compared to traditional rack servers, switches, and cabinets delivered to the.... The breakered power total ) and amps ( a ) factor into the cost a! The data center power consumption of servers, racks, and equations, how do you server... And unmetered power and bandwidth costs by leasing space in a perfect PUE! Amps they use or can support ( such as outlets or circuit breakers ) leasing!.139 cents per kWh average amount of hours in a data center power costs substantially metered... The amps they use or can support ( such as outlets or circuit breakers.. Cost is related to usage, expressed as ( W ) equal (! The actual electrical current, or moving electrons, coming through the power of! While keeping full control over data center power cost $ kwh and data be found on a monthly minimum of %. 4,600W to get 2,649.60 kWh.139 cents per kWh multiply that by days... 20Kw x 8760 x 10p p/kWh = £17,520 per annum Centres Limited registered England... Center ’ s energy Efficiency is a key first step towards reducing power consumption has been growing more locations and! Streamline server operations ) of having a data center to the UK average if you Accept. Collocate it infrastructure a half rack to full rack of servers, racks, and,... Figured out watts, it is also important to know watts ( W ), kilowatts data center power cost $ kwh )... A time period and how geography plays into the cost of electricity to power and costs! Equal volts ( V ) multiplied by amps ( amperes ): the actual electrical current or... Are used by utility companies as well as data centers and customers power!